MODEL TYPE
|
E3 SPC 1210
|
E3 SPC 3210
|
E3 SPC 3420
|
E3 SPC 3630
|
| Size |
55H
x 30B x 20Dcm |
55H
x 30B x 20Dcm |
55H
x 30B x 20Dcm |
55H
x 30B x 20Dcm - 2 units |
| Weight
|
18
Kg |
25
Kg |
28
Kg |
21
Kg + 27 Kg |
| Casing |
Vented
Power coated Galvanised |
Vented
Power coated Galvanised |
Vented
Power coated Galvanised |
Vented
Power coated Galvanised |
| Mounting |
Wall
mounted - brackets |
Wall
mounted - brackets |
Wall
mounted - brackets |
Wall
mounted - brackets |
| Voltage |
All
voltage levels compatible |
All
voltage levels compatible |
All
voltage levels compatible20
|
All
voltage levels compatible |
| Phase |
Single
Phase |
3~Phase |
3~Phase |
3~Phase |
| Lamp
Type |
All
Fluorescent (excludes some electronic ballasts)
and HID |
All
Fluorescent (excludes some electronic ballasts)
and HID |
All
Fluorescent (excludes some electronic ballasts)
and HID |
All
Fluorescent (excludes some electronic ballasts)
and HID |
| Max
Load - Uncontrolled |
40
amps = approx 200 36W lamps - Single phase |
15
amps per phase = approx 230 36W lamps over
3~phases |
25
amps /phase = approx 420 36W lamps over 3~phases |
40
amps / phase = approx 600 36W lamps over 3~phases |
| Connection |
Direct
to standard MCB - included in integrated sub
board - 6mm |
Direct
to standard MCB - included in integrated sub
board - 1.5mm |
Direct
to standard MCB - included in integrated sub
board - 2.5mm |
Direct
to standard MCB - included in integrated sub
board - 6mm |
| Output |
Up
to 18 circuits on integrated sub-board |
Up
to 17 circuits on integrated sub-board balanced
over 3 phases |
Up
to 17 circuits on integrated sub-board balanced
over 3 phases |
Up
to 20 circuits on integrated sub-board balanced
over 3 phases |
| Voltage
Out |
-13.75% |
-13.75% |
-13.75% |
-13.75% |
| Load
Out VA |
-
33% nominal |
-33%
Nominal |
-33%
Nominal |
-33%
Nominal |
| Power
Factor |
improved
+5 - 20% (site dependent) |
improved
+5 - 20% (site dependent) |
improved
+5 - 20% (site dependent) |
improved
+5 - 20% (site dependent) |
| kWh
Reduced |
-25%
to 33% |
-25%
to 33% |
-25%
to 33% |
-25%
to 33% |
| Lumen
output |
Approx
95% - Fluorescent |
Approx
95% - Fluorescent |
Approx
95% - Fluorescent |
Approx
95% - Fluorescent |
| Lumens
/ Watt - efficacy |
(No
SPC) -100% (SPC) -128.5% |
(No
SPC) - 100% (SPC) - 128.5% |
(No
SPC) - 100% (SPC) - 128.5% |
(NO
SPC) - 100% (SPC) - 128.5% |
| CO2-e
reduced |
Full Load (5000
light hrs / year) - 33 tonnes / annum (approx) |
Full Load (5000
light hrs / year) - 38 tonnes / annum (approx) |
Full Load (5000
light hrs / year) - 63 tonnes / annum (approx) |
Full Load (5000
light hrs / year) - 100 tonnes / annum (approx) |